WELCOME TO THRU RAINBOW SA
info@thrurainbow.co.za
+27 83 350 2463
Be Seen & Heard
Controllers
Controllers

47226 - TRC022  Control unit (6 Wire Controller)

  • A control unit used with TRF060 flasher unit
  • 1.5 A maximum output switching current
  • 2-meter harness (extra per request)
  • Identifiable as a 6-wire control

Our ultra compact Siren Driver System controllers consolidate all your vehicle’s warning controls into one unit. When it is important to be seen and heard, Thru Rainbow offers siren controller systems that provide versatile control of light and siren functions in one single unit.

 

 

47221 - TRF022 2 Channel Flasher unit (5 Wire Controller)

  • Used for light bars with less than 10 modules (0.3 A)
  • 2 channel flasher unit with control
  • 1.5 A maximum output per channel
  • Flasher pattern: 6
  • 2-meter harness (extra per request)
  • Identifiable as a 5-wire control

47221-2SW - TRF022 2 Channel Flasher Unit

with 2 ON-OFF switches

  • Used for light bars with less than 10 modules (0.3 A)               2 auxiliary
  • 2 channel flasher unit with control & X2 ON/OFF switch
  • 1.5 A maximum output per channel
  • Flasher pattern: 6
  • 2-meter harness (extra per request)
  • Identifiable as a 5-wire control with a 2 switches

47226-2SW - TRC022 Control Unit with X2 ON-OFF switches

  • A control unit used with TRF060 flasher unit and X2 auxiliary switching
  • 1.5 A maximum output switching current
  • 2-meter harness (extra per request)
  • Identifiable as a 6-wire control with 2 switches

47221-SW - TRF022 2 Channel Flasher Unit with a switch

  • Used for light bars with less than 10 modules (0.3 A) auxiliary
  • 2 channel flasher unit with control & ON/OFF switch
  • 1.5 A maximum output per channel
  • Flasher pattern: 6
  • 2-meter harness (extra per request)
  • Identifiable as a 5-wire control with a switch

47226-SW - TRC022 Control Unit with ON-OFF switch

  • A control unit Used with TRF060 flasher unit and auxiliary switching
  • 1.5 A maximum output switching current
  • 2-meter harness (extra per request)
  • Identifiable as a 6-wire control with a switch

47221-NPA-C - TRF022 2 Channel Flasher Unit with NPA controller

  • Used for lightbars with less than 10 modules (0.3 A) & Non-PA system
  • 2 channel flasher unit with control & Non-PA system
  • 1.5 A maximum output per channel
  • Flasher pattern: 6
  • 2-meter harness (extra per request)
  • Identifiable as a 5-wire control with Non-PA system

47226-NPA-C- TRF022 Control unit with NPA controller

  • A control unit Used with TRF060 flasher unit and Non-PA siren
  • 1.5 A maximum output switching current
  • 2-meter harness (extra per request)
  • Identifiable as a 6-wire control with Non-PA siren